Below is a table showing Sun Hydraulics’ recommended torque specifications for installing cartridge valves.
The table is organized by valve series and lists the recommended tightening torque as well as the applicable cavity or cavities for each valve.
3/16″ (4,8 mm) Internal Hex 3/8-24 UNF Thread Installation Torque: (11-14 Nm), T-382A
7/8″ (22,4 mm) Hex M16 Thread Installation Torque: (27-33 Nm) T-8A T-9A
3/4″ (19,1 mm) Hex M16 Thread Installation Torque: (27-33 Nm) T-162A T-163A
7/8″ (22,2 mm) Hex M20 Thread Installation Torque: (40-50 Nm) T-10A T-13A T-11A T-21A T-31A T-51A T-61A
1-1/8″ (28,6 mm) Hex 1″-14 UNS Thread Installation Torque: (60-70 Nm) T-3A T-5A T-2A T-22A T-32A T-52A T-62A
1-1/4″ (31,8 mm) Hex M36 Thread Installation Torque: (200-215 Nm) T-16A T-17A T-23A T-33A T-53A T-63A
1-5/8″ (41,3 mm) Hex M48 Thread Installation Torque: (475-500 Nm) T-18A T-18AU T-19A T-19AU T-24A T-34A T-64A