Hydnet - the specialist in intelligent hydraulic systems
Contact
Solenoid flow control valves

Solenoid flow control valves

A solenoid flow control valve is a common component in hydraulic systems and is used to regulate or restrict the flow rate of fluid. The valve does not directly affect the pressure, but instead controls how quickly a function is performed—for example, how fast a cylinder moves or how quickly a hydraulic motor rotates. Flow control valves are used to manage the flow in one or more functions, for instance by restricting flow, distributing it to multiple functions or prioritizing flow to a specific function.

Read more »
Flow control valve

2 ports, FLeX series, electro-proportional throttle, flow 2-1, pilot operated, normally closed. Coil options low power 3000 psi, high power 5000 psi or explosion proof.

Model
Cavity
Nominal Capacity
FPBF
T-162A
20 lpm (5 gpm)
PDF
STP
FPBD
T-162A
20 lpm (5 gpm)
PDF
STP
Flow control valve

2 ports, FLeX series, electro-proportional throttle with reverse flow check, flow 2-1, pilot operated, normally closed. Coil options low power 3000 psi, high power 5000 psi or explosion proof.

Model
Cavity
Nominal Capacity
FPBG
T-162A
20 lpm (5 gpm)
PDF
STP
FPBE
T-162A
20 lpm (5 gpm)
PDF
Proportional valve

3 way, electro proportional throttle

Model
Cavity
Nominal Capacity
FMDA-*A*
T-11A
0,1-9 gpm (0,4-34 lpm)
PDF
STP
FMDA-*B*
T-11A
0,1-1,6 gpm (0,4-6,1 lpm)
PDF
STP
FMDA-*C*
T-11A
0,1-1,6 gpm (0,4-6,1 lpm)
PDF
STP
FMDA-*D*
T-11A
0,1-1,6 gpm (0,4-6,1 lpm)
PDF
STP
FMDB-*A*
T-11A
0,1-9 gpm (0,4-34 lpm)
PDF
STP
FMDB-*B*
T-11A
0,1-1,6 gpm (0,4-6,1 lpm)
PDF
STP
FMDB-*C*
T-11A
0,1-1,6 gpm (0,4-6,1 lpm)
PDF
STP
Flow control valve

2 ports, FLeX series, electro-proportional throttle, flow 2-1, pilot operated, normally open. Coil options low power 3000 psi, high power 5000 psi or explosion proof.

Model
Cavity
Nominal Capacity
FPBI
T-162A
20 lpm (5 gpm)
PDF
FPBM
T-162A
20 lpm (5 gpm)
PDF
Flow control valve

2 ports, FLeX series, electro-proportional throttle with reverse flow check, flow 2-1, pilot operated, normally open. Coil options low power 3000 psi, high power 5000 psi or explosion proof.

Model
Cavity
Nominal Capacity
FPBJ
T-162A
20 lpm (5 gpm)
PDF
FPBN
T-162A
20 lpm (5 gpm)
PDF
Flow control valve

2 ports, FLeX series, electro-proportional throttle with blocking poppet valve, flow 2-1, direct-acting, normally open. Coil options high power 5000 psi or explosion proof.

Model
Cavity
Nominal Capacity
FPBU
T-162A
2,6 gpm (9,8 lpm)
PDF
Flow control valve

3 way, Direct acting, Electro-proportional, Bypass/Restrictive Priority Flow Control Valve

Model
Cavity
Nominal Capacity
FREP-*A*
T-17A
15 gpm (60 lpm )
PDF
STP
FREP-*B*
T-17A
22 gpm (88 lpm)
PDF
STP
FREP-*C*
T-17A
15 gpm (60 lpm )
PDF
STP
Flow control valve

4 ports, normally closed, dual path, proportional throttle

Model
Cavity
Nominal Capacity
FTCA
T-52AD
30 gpm (120 lpm)
PDF
STP
FTDA
T-52AD
15 gpm (60 lpm )
PDF
STP
FTEA
T-53AD
50 gpm (200 lpm )
PDF
STP
FTFA
T-53AD
25 gpm (95 lpm )
PDF
STP
Flow control valve

3-way, meter-in, electro-proportional throttle

Model
Cavity
Nominal Capacity
FMDF-*A*
T-11A
4 gpm (15 lpm )
PDF
STP
FMDF-*B*
T-11A
1,6 gpm (6,1 lpm)
PDF
STP
FMDF-*C*
T-11A
1,6 gpm (6,1 lpm)
PDF
STP
FMDF-*D*
T-11A
1,6 gpm (6,1 lpm)
PDF
STP
Flow control valve

3-way, meter-in, electro-proportional throttle

Model
Cavity
Nominal Capacity
FMDG-*A*
T-11A
0,1-4 gpm (0,4-15 lpm)
PDF
STP
FMDG-*B*
T-11A
0,1-1,6 gpm (0,4-6,1 lpm)
PDF
STP
FMDG-*C*
T-11A
0,1-1,6 gpm (0,4-6,1 lpm)
PDF
STP
Flow control valve

4 ports, normally closed, dual path, proportional throttle wth position indicating switch

Model
Cavity
Nominal Capacity
FTCAZ
T-52AD
30 gpm (120 lpm)
PDF
STP
FTDAZ
T-52AD
15 gpm (60 lpm )
PDF
STP
FTEAZ
T-53AD
50 gpm (200 lpm )
PDF
STP
FTFAZ
T-53AD
25 gpm (95 lpm )
PDF
STP
Flow control valve

2 ports, electro proportional throttle NC

Model
Cavity
Nominal Capacity
FPCC-*A*
T-13A
0,15-3,5 gpm (0,6-14 lpm)
PDF
STP
FPCC-*B*
T-13A
0,1-1,5 gpm (0,4-6 lpm)
PDF
STP
FPCC-*C*
T-13A
0,1-1,5 gpm (0,4-6 lpm)
PDF
STP
FPCC-*D*
T-13A
0,1-1,5 gpm (0,4-6 lpm)
PDF
STP
Fullt justerbar prioritetsventil
Flow control valve

3 way, Direct acting, Electro-proportional, Bypass/Restrictive Priority Flow Control Valve

Model
Cavity
Nominal Capacity
FREL-*A*
T-17A
17 gpm (66,5 lpm)
PDF
STP
Flow control valve

2 ports, electro proportional throttle NC

Model
Cavity
Nominal Capacity
FPFK-*B*
T-5A
40 lpm (10 gpm)
PDF
STP
FPFK-*D*
T-5A
40 lpm (10 gpm)
PDF
STP
FPHK-*A*
T-16A
40 gpm (160 lpm)
PDF
STP
FPHK-*C*
T-16A
60 gpm ( 240 lpm)
PDF
STP
FPHK-*E*
T-16A
40 gpm (160 lpm)
PDF
STP
Flow control valve

2 ports, electro proportional throttle NO

Model
Cavity
Nominal Capacity
FPCH-*A*
T-13A
0,25-7 gpm (1-28 lpm)
PDF
STP
FPCH-*B*
T-13A
0,1-1,5 gpm (0,4-6 lpm)
PDF
STP
FPCH-*C*
T-13A
0,1-1,5 gpm (0,4-6 lpm)
PDF
STP
Flow control valve

Pilot-operated, normally closed, electro-proportional throttle with reverse flow check – (740 Series).

Model
Cavity
Nominal Capacity
FPJP
T-18A
114 gpm (431 lpm)
PDF
STP

Electric control

To enable electric control, the flow control valve is combined with a solenoid coil. Solenoid coils from Sun Hydraulics are available in various models with different connector types and voltage options, providing high flexibility for adaptation to different applications. The solenoids are compatible with both on/off functions and proportional control. For proportional control, the XMD controller is recommended, which can be easily configured via a mobile app or computer software.

One-way or two-way

Flow control valves are available in two basic types: one-way (unidirectional) and two-way (bidirectional). A one-way flow control valve regulates flow in one direction only, while allowing unrestricted flow in the opposite direction. In contrast, a two-way flow control valve is used when flow needs to be controlled in both directions, making it ideal for applications where movement or pressure must be regulated both ways.

Proportional or on/off control

Proportional flow control valves are operated by an electrical signal and allow for precise, stepless regulation of flow, providing a higher degree of control and accuracy. The valve opens only to the extent corresponding to the level of the control signal. On/off flow control valves, on the other hand, are either fully open or fully closed. These are suitable for simpler applications where exact flow regulation is not required.

Safety and energy efficiency

Flow control valves can also serve as overload protection in a system. If the flow becomes too high, the valve can automatically reduce it to protect other components from damage due to excessive load or pressure. Additionally, these valves can contribute to energy savings by reducing unnecessary flow, thereby lowering the system’s overall energy consumption.

Hittar du inte riktigt vad du söker?
Kontakta oss så hjälper vi dig!

Vi vet att varje projekt har sina unika behov. Om du inte hittar den information eller produkt du letar efter i vår produktkatalog eller kunskapsbank är du alltid välkommen att höra av dig. Våra specialister guidar dig rätt och hjälper dig hitta den bästa lösningen.

Här har vi samlat nyttig teknikinformation

I vår kunskapsbank har vi samlat information om våra produkter och dess funktioner. Det kan vara allt från hur SUN Hydraulics skapar sina modellbeteckningar till hur transmissionssystem fungerar eller djupdykning i en ventilfunktion.

Hydnet
EA Rosengrens gata 29
421 32 Västra Frölunda

+46 31 - 499 490
info@hydnet.se

Products

  • Cartridge valves
  • Manifolds
  • Hydraulic valves
  • Electro hydraulics
  • ACE Automation control
  • ACE Motion control
  • ACE Vibration control
  • ACE Safety products
  • Schroeder Filters
  • Rexroth Pumpar och motorer
  • Rexroth Mobil- & kompakthydraulik
  • Accessories

Pages

  • System solutions
  • About Hydnet
  • Services
  • News
  • Partners
  • Contact
  • My Hydnet

Policies

  • Integritetspolicy
  • Cookies
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.